| HP EML-E/SUN StorageTek SL500 CLI Help |
HP EML-E/SUN StorageTek SL500 CLI HelpOEM>> help alladdress < <library> | host > This command translates the given address to the other format. If you enter the library address you will get a host address. If you enter a host address you will get a library address. A library address is specified as L,M,R,C. The host address is specified as decimal or hex with a leading '0x'. Example: 'address 500' or 'address 0x1fe' or 'address 0,1,4,2' autoaudit print Show the current setting of automatic element auditing. autoaudit <on|off> Enable and disable automatic element auditing. autoclean print Show the library's current 'autoclean' option setting autoclean <on|off> Set the 'autoclean on/off' option. This option controls whether or not the library performs drive cleaning automatically or not. Setting option to 'on' will drives to be automatically cleaned when needed. Setting option to 'off' will disable automatic drive cleaning. If the host software is handling drive cleaning the option should be off. cap <module#> <io|storage> Configure the specified module's CAP as I/O or as storage cells. cartridge print Show location, volser, and media type for all cartridges. cartridge print reserved Show location, volser, and media type for reserved cartridges. cleancartcount print Show the library's current list of cleaning cartridges and cleaning counts. cleancartcount <label> <count> Set the number of cleans for a given cartridge label. The cartridge must be a cleaning cartridge and must be in the cleaning list. The cleaning list is not complete until audit is finished. cleanwarnthreshold print Show the library's current warning threshold count for cleaning cartridges. cleanwarnthreshold <count> <drivetype> Set a warning threshold count for the number of cleans a cartridge can perform for a given drive type before a warning is issued. <drivetype> is 'lto' or 'dlt'. If the value is set to 0 no warning will be issued. codeload 'filename' Load in new code image. date <print> | <mm/dd/yyyy> Print or set the library's date value. Takes the library off of
network time if set.diagcaps Diagnose the CAPs. diagdemo <diagdemo> <count> <mode> Moves any cartridge from a random source to a random destination. Example: diagdemo 10 silent Example: diagdemo 100 nonsilent diagdoor Diagnose the Door. diaggetput <diaggetput> <diag type> <source addr|random> <destination addr|random|all> <count> <mode> Moves the diagnostic cartridge from the specified or random source to the specified or random destination. The "all" parameter refers to all drives. Example: diaggetput cellToCell 0,1,2,1 0,1,3,3 10 silent Example: diaggetput cellToCell 0,1,2,1 0,1,5,2 5 nonsilent Example: diaggetput cellToDrive 0,1,2,1 0,1,2,9 5 nonsilent Example: diaggetput cellToDrive 0,1,3,2 all 5 silent diagquery <diagquery> <diag type> <count> <mode> Example: diagquery basicHealth 10 silent Example: diagquery basicHealth 10 nonsilent diagselftest <src address> <loop count> <mode> Performs library basic health diagnostic. Then does get/put operations from the src address to random empty cells in the library. Then performs mounts from the src address to all drives attached to the library. The test requires atleast one piece of media and one drive. Example: diagselftest 0,1,1,2 2 silent Example: diagselftest 0,2,1,1 10 nonsilent diagstop Stop the 'Diag' operation. driveFaultLEDs Show the library's drive enclosure fault LEDs state drive all Show drive information for all drives. drive <addr> clean Clean the specified drive. A label may be specified when prompted. drive <addr> getconfig Show the specified drive's fibre channel or SCSI configuration. drive <addr> gettime Show the specified drive's Time-of-Day (TOD) clock setting. drive <addr> info Show the specified drive's information. drive <addr> load Initiate the specified drive's cartridge load process. drive <addr> reset Reset the specified drive. drive <addr> rewindunload Commands the specified drive to rewind then unload its cartridge. drive <addr> setconfig Set the specified drive's fibre channel or SCSI configuration. drive <addr> settime Set the specified drive's Time-of-Day (TOD) clock. drive <addr> state Show the specified drive's operational state. entereject <entereject> <type> Depending on the type selected (enter or eject) the following occurs: enter - CAP door will open and you may enter the diagnostic and cleaning cartridges eject - You will be prompted to enter the cartridges to be ejected. If an error occurs during the eject operation the command will be terminated. The CAP door will be opened if any cartridges were moved to the CAP magazine. Example: entereject eject fastload print Show the library's current 'fastload' option setting fastload <on|off> Set the 'fastload on/off' option. This option controls whether or not the library performs a fastload when loading drives. Setting option to 'on' will cause fastloads to be used. Setting option to 'off' will cause normal drive loads. This is the Default. Fastloads do not wait for the drive to be 'ready' after the load command has been issued to the drive. fetch <addr> Retrieve the cartridge from the specified address to the Robot hand. frameinfo print Show the library's frame information (i.e, frame serial number, World Wide Name (WWN)) and the Vendor. label print Show the library's current 'label' option setting label <required|notrequired> Set the 'label required/not required' option. This option controls whether or not a cell that appears empty is touched to see if a cartridge is present in that cell. Setting option to 'notrequired' will cause all cells except drives to be verified (i.e., cartridge labels are not required). Setting option to 'required' will cause only CAP cells to be verified (i.e., cartridge labels are required). lib getconfig Show library configuration. lib setconfig Set the specified library's fibre channel or SCSI configuration. libstate print Shows the state and location of all mechanisms log clear all Clear all output log files. log clear log_scsi_ck WARNING - removes log_scsi_ck file. move <source addr> <dest addr> move the cartridge from the specified source to the specified destination. network ip <ip addr> Set the library's IP address to the specified IP address. (public port configuration only) network ip address add <ip addr[/netmask]> dev <public|private> Add an IP address for public or private port. network ip address del <ip addr[/netmask]> dev <public|private> Delete an IP address for public or private port. NOTES: - If the netmask parameter in <ip addr[/netmask]> is unspecified, then the default value of 32 (255.255.255.255) is used. - The allowed netmask values are 1 through 32. network ip address show Display IP address information for public and private ports. network mask <IP address> (public port configuration only) Set the library's subnet mask to the specified IP address. network name <machine network name> Set the library's machine name to the specified host ID. (public port configuration only) network gateway <IP address | none> Set the gateway IP address. (optional) network print Print the library's network settings. (public port config only) network restart Restart the library's network interface. IMPORTANT REMINDER: All network parameters should be configured before issuing the 'network restart' command. orientlabel print Show the library's current host and Op Panel 'orientlabel' settings orientlabel <host|oppanel> <all|left8pre|left8|left7|left6|right6|right7|right8> Set either the host or operator panel 'orientlabel' parameter. This option causes the barcode label on the tape cartridge to be presented to a specifed interface ( host or operator panel ) as fewer character and justified left or right. The orientation setting of 'all' will present the entire label. When this setting is in effect it is assumed there is no domain and type fields, and none are returned or checked for compatibility. The orientation setting of 'left' will start using barcode characters from left and proceeding the number specified. A right orientation setting will use a number of characters specified starting from the right. The setting left8pre prefixes the label with the last 2 characters. Example barcode 'ABCDEFGH' setting left7 shows: 'ABCDEFG' setting all shows: 'ABCDEFGH' setting left8pre shows: 'GHABCDEF' setting right6 shows: 'CDEFGH' park Park the robot in the home position so the robot can be removed. Once this command is issued, the robot will need to be removed or rebooted. This command does not behave the same as the door open button. It will not ti meout, and does not return the library to a useable state until after a reboot. print log <all> | <error> | <warning> | <info> | <trace.0> | <trace> | <diag> | <config> | <scsi> | <scsi_ck> | <syslog> Print one or all of the library's diagnostic logs. To create a text file of the log using Hyperterminal, enable text capture to a local file before printing the desired log. pushCapButton Initiates a CAP open button press. pushDoorButton Initiates a Door open button press. put <dest addr> Place the cartridge from the robot hand into the specified address reboot Restart the operating system wich initiates library initialization. recalibrate <address> Recalibrate a single specified address. recalibrate <start address> <end address> Recalibrate a range of addresses. recalibrate all Recalibrate the entire library. reserved print Show the library's current reserved cell count. reserved <number of cells> Set the maximum number of reserved(playground) library storage cells in the library. resetdefaults Reset library defaults: admin password='', Load Ports = I/O, network =
DHCP.barcode is 8 characters left aligned (left8) for both host and oppanel, reserved slots = 0, inventory mode is labels required, service inventory set to off. resetoppanel Cause a hard Op Panel reset to occur. scanaudit print Show the library's current 'scanaudit' option setting scanaudit <on|off> Set the 'scanaudit on/off' option. This option controls whether or not the library performs a scanning audit. Setting option to 'on' will casue scanning audits. This is the default. Setting option to 'off' will disable scanning audits. Hard to read labels are more difficult to read with scanning audit, but it is faster than a reading each individual location. This setting will have no effect if labels are not required because scanning audits are not performed in this case. serialnumber <print> | <s/n> session timeout <minutes> Sets the timeout of this session. If no characters are typed within this time frame, the user is logged off. shutdown Orderly shutdown of library statistics robot print Show the total number of get/put operations and retries. statistics library print Show number of Boots/initializations. Show cumulative uptime (updated hourly). Show uptime since last boot. statistics media print <byDate | byMedia | byDrive> Display various drive and media events useful for isolating drive or media errors. The event types are MediaError, LoadError, UnloadError, LoadRetry, and DriveError The output is sorted by one of the following key words byDate - (default) displays output sorted by date/time with the most recent events first byMedia - groups the output by Volume ID in order of the media with the highest number of entries first byDrive - groups the output by Drive Serial Num in order of the drive with the highest number of entries first statisticsreset <robot | media > For <robot>, reset the total number of get/put operations and retries. For <media>, reset the media drive event statistics time <print> | <network> | <hh:mm:ss> | <hh:mm> Print or set the library's time value. Takes the library off of network time if set. The network option re-enables network time. Depending on the network, it may take several minutes to revert back to network time. trace <trace type> on/off Example: trace tti-dbg-01 on Turns tti debug log trace on for drive id 1 Example: trace tti-dbg-18 off Turns tti debug log trace off for drive id 18 Example: trace interface manager-debug on Turns IFM debug log trace on List of Trace Type Strings That Can Be Used With Trace: tti-dbg-xx ( xx is the drive id ) drive-tti-xx ( xx is the drive id ) scsi scsi-engine scsi-server interface-manager interface-manager-debug diag event-manager OpPanel service-interface VMonitor object-data-store access-manager sensor-manager opel-server move-sequence lms upsidedowndetect print Show the library's current 'upsidedowndetect' option setting upsidedowndetect <on|off> Set the 'upsidedowndetect on/off' option. This option controls whether or not the library detects upside down cartridges. This setting is only valid for multi-media modules. LTO modules mechanically restrict upside down cartridges. Setting option to 'on' will enable checking. This is the default. Setting option to 'off' will disable checking. version print Show all library version information
|