Добавить в закладки

AddThis Social Bookmark Button

Последние комментарии

Авторизация



  
Home Помощь в настройке HP EML-E/SUN StorageTek SL500 CLI Help
HP EML-E/SUN StorageTek SL500 CLI Help

HP EML-E/SUN StorageTek SL500 CLI Help

OEM>> help all
address < <library> | host >
   This command translates the given address to the other format.
   If you enter the library address you will get a host address.
   If you enter a host address you will get a library address.
   A library address is specified as L,M,R,C.
   The host address is specified as decimal or hex with a leading '0x'.
    Example:  'address 500' or 'address 0x1fe' or 'address 0,1,4,2'
autoaudit print
   Show the current setting of automatic element auditing.
autoaudit <on|off>
   Enable and disable automatic element auditing.
autoclean print
   Show the library's current 'autoclean' option setting
autoclean <on|off>
   Set the 'autoclean on/off' option.
   This option controls whether or not the library performs drive cleaning automatically or not.
   Setting option to 'on' will drives to be automatically cleaned when needed.
   Setting option to 'off' will disable automatic drive cleaning.
    If the host software is handling drive cleaning the option should be off.
cap <module#> <io|storage>
   Configure the specified module's CAP as I/O or as storage cells.
cartridge print
   Show location, volser, and media type for all cartridges.
cartridge print reserved
   Show location, volser, and media type for reserved cartridges.
cleancartcount print
   Show the library's current list of cleaning cartridges and cleaning counts.
cleancartcount <label> <count>
   Set the number of cleans for a given cartridge label.
   The cartridge must be a cleaning cartridge and must be in the cleaning list. The cleaning list is not complete until audit is finished.
cleanwarnthreshold print
   Show the library's current warning threshold count for cleaning cartridges.
cleanwarnthreshold <count> <drivetype>
   Set a warning threshold count for the number of cleans a cartridge can perform for a given drive type before a warning is issued.
   <drivetype> is 'lto' or 'dlt'.
   If the value is set to 0 no warning will be issued.
codeload 'filename'
   Load in new code image.
date <print> | <mm/dd/yyyy>
   Print or set the library's date value. Takes the library off of Glossary Link network time if set.
diagcaps
   Diagnose the CAPs.
diagdemo <diagdemo> <count> <mode>
   Moves any cartridge from a random source to a random destination.
   Example: diagdemo 10 silent
   Example: diagdemo 100 nonsilent
diagdoor
   Diagnose the Door.
diaggetput  <diaggetput> <diag type> <source addr|random>
            <destination addr|random|all> <count> <mode>
   Moves the diagnostic cartridge from the specified or random source
   to the specified or random destination.
   The "all" parameter refers to all drives.
   Example: diaggetput cellToCell 0,1,2,1 0,1,3,3 10 silent
   Example: diaggetput cellToCell 0,1,2,1 0,1,5,2 5  nonsilent
   Example: diaggetput cellToDrive 0,1,2,1 0,1,2,9 5  nonsilent
   Example: diaggetput cellToDrive 0,1,3,2 all 5  silent
diagquery <diagquery> <diag type> <count> <mode>
   Example: diagquery basicHealth 10 silent
   Example: diagquery basicHealth 10 nonsilent
diagselftest <src address> <loop count> <mode>
    Performs library basic health diagnostic. Then does get/put
    operations from the src address to random empty cells in the
    library. Then performs mounts from the src address to all drives
    attached to the library. The test requires atleast one piece of media
    and one drive.
  Example: diagselftest 0,1,1,2 2 silent
  Example: diagselftest 0,2,1,1 10 nonsilent
diagstop
   Stop the 'Diag' operation.
driveFaultLEDs
   Show the library's drive enclosure fault LEDs state
drive all
   Show drive information for all drives.
drive <addr> clean
   Clean the specified drive. A label may be specified when prompted.
drive <addr> getconfig
   Show the specified drive's fibre channel or SCSI configuration.
drive <addr> gettime
   Show the specified drive's Time-of-Day (TOD) clock setting.
drive <addr> info
   Show the specified drive's information.
drive <addr> load
   Initiate the specified drive's cartridge load process.
drive <addr> reset
   Reset the specified drive.
drive <addr> rewindunload
   Commands the specified drive to rewind then unload its cartridge.
drive <addr> setconfig
   Set the specified drive's fibre channel or SCSI configuration.
drive <addr> settime
   Set the specified drive's Time-of-Day (TOD) clock.
drive <addr> state
   Show the specified drive's operational state.
entereject  <entereject> <type>
   Depending on the type selected (enter or eject) the following occurs:
      enter - CAP door will open and you may enter the diagnostic and cleaning cartridges
      eject - You will be prompted to enter the cartridges to be ejected.
              If an error occurs during the eject operation the command will be terminated. The CAP door will be opened if any cartridges were moved to the CAP magazine.
    Example: entereject eject
fastload print
   Show the library's current 'fastload' option setting
fastload <on|off>
   Set the 'fastload on/off' option.
    This option controls whether or not the library performs a fastload when loading drives.
   Setting option to 'on' will cause fastloads to be used.
   Setting option to 'off' will cause normal drive loads. This is the Default.
    Fastloads do not wait for the drive to be 'ready' after the load command has been issued to the drive.
fetch <addr>
   Retrieve the cartridge from the specified address to the Robot hand.
frameinfo print
   Show the library's frame information (i.e, frame serial number,
   World Wide Name (WWN)) and the Vendor.
label print
   Show the library's current 'label' option setting
label <required|notrequired>
   Set the 'label required/not required' option.
   This option controls whether or not a cell that appears empty is touched to see if a cartridge is present in that cell.
   Setting option to 'notrequired' will cause all cells except drives to be verified (i.e., cartridge labels are not required).
   Setting option to 'required' will cause only CAP cells to be verified (i.e., cartridge labels are required).
lib getconfig
   Show library configuration.
lib setconfig
   Set the specified library's fibre channel or SCSI configuration.
libstate print
   Shows the state and location of all mechanisms
log clear all
   Clear all output log files.
log clear log_scsi_ck
   WARNING - removes log_scsi_ck file.
move <source addr> <dest addr>
   move the cartridge from the specified source to the specified destination.
network ip <ip addr>
   Set the library's IP address to the specified IP address.
   (public port configuration only)
network ip address add <ip addr[/netmask]> dev <public|private>
   Add an IP address for public or private port.
network ip address del <ip addr[/netmask]> dev <public|private>
   Delete an IP address for public or private port.
   NOTES:
   - If the netmask parameter in <ip addr[/netmask]> is unspecified,
     then the default value of 32 (255.255.255.255) is used.
   - The allowed netmask values are 1 through 32.
network ip address show
   Display IP address information for public and private ports.
network mask <IP address> (public port configuration only)
   Set the library's subnet mask to the specified IP address.
network name <machine network name>
   Set the library's machine name to the specified host ID.
   (public port configuration only)
network gateway <IP address | none>
   Set the gateway IP address. (optional)
network print
   Print the library's network settings. (public port config only)
network restart
   Restart the library's network interface.
IMPORTANT REMINDER: All network parameters should be configured before
   issuing the 'network restart' command.
orientlabel print
   Show the library's current host and Op Panel 'orientlabel' settings
orientlabel <host|oppanel> <all|left8pre|left8|left7|left6|right6|right7|right8>
   Set either the host or operator panel 'orientlabel' parameter.
   This option causes the barcode label on the tape cartridge to be presented to a specifed interface ( host or operator panel ) as fewer character and justified left or right.
   The orientation setting of 'all' will present the entire label. When this
   setting is in effect it is assumed there is no domain and type fields, and none are returned or checked for compatibility.
   The orientation setting of 'left' will start using barcode characters from left and proceeding the number specified. A right orientation setting will use a number of characters specified starting from the right.
   The setting left8pre prefixes the label with the last 2 characters.
      Example barcode                 'ABCDEFGH'
         setting left7    shows:      'ABCDEFG'
         setting all      shows:      'ABCDEFGH'
         setting left8pre shows:      'GHABCDEF'
         setting right6   shows:      'CDEFGH'
park
   Park the robot in the home position so the robot can be removed.
   Once this command is issued, the robot will need to be removed or rebooted.
   This command does not behave the same as the door open button. It will not ti
meout,
   and does not return the library to a useable state until after a reboot.
print log <all> | <error> | <warning> | <info> | <trace.0> | <trace> |
          <diag> | <config> | <scsi> | <scsi_ck> | <syslog>
   Print one or all of the library's diagnostic logs. To create a text file of the log using Hyperterminal, enable text capture to a local file before printing the desired log.
pushCapButton
   Initiates a CAP open button press.
pushDoorButton
   Initiates a Door open button press.
put <dest addr>
   Place the cartridge from the robot hand into the specified address
reboot
   Restart the operating system wich initiates library initialization.
recalibrate <address>
   Recalibrate a single specified address.
recalibrate <start address> <end address>
   Recalibrate a range of addresses.
recalibrate all
   Recalibrate the entire library.
reserved print
   Show the library's current reserved cell count.
reserved <number of cells>
   Set the maximum number of reserved(playground) library storage cells
   in the library.
resetdefaults
   Reset library defaults: admin password='', Load Ports = I/O, network = Glossary Link DHCP.
      barcode is 8 characters left aligned (left8) for both host and oppanel, reserved slots = 0, inventory mode is labels required, service inventory set to off.
resetoppanel
   Cause a hard Op Panel reset to occur.
scanaudit print
   Show the library's current 'scanaudit' option setting
scanaudit <on|off>
   Set the 'scanaudit on/off' option.
   This option controls whether or not the library performs a scanning audit.
   Setting option to 'on' will casue scanning audits. This is the default.
   Setting option to 'off' will disable scanning audits.
   Hard to read labels are more difficult to read with scanning audit, but it is faster than a reading each individual location.
   This setting will have no effect if labels are not required because scanning audits are not performed in this case.
serialnumber <print> | <s/n>
session timeout <minutes>
   Sets the timeout of this session. If no characters are typed within this time frame,  the user is logged off.
shutdown
   Orderly shutdown of library
statistics robot print
     Show the total number of get/put operations and retries.
statistics library print
     Show number of Boots/initializations.
     Show cumulative uptime (updated hourly).
     Show uptime since last boot.
statistics media print <byDate | byMedia | byDrive>
     Display various drive and media events useful for isolating drive or media errors. The event types are MediaError, LoadError, UnloadError, LoadRetry, and DriveError  The output is sorted by one of the following key words
       byDate - (default) displays output sorted by date/time with the most recent events first
       byMedia - groups the output by Volume ID in order of the media with the highest number of entries first
       byDrive - groups the output by Drive Serial Num in order of the drive with the highest number of entries first
statisticsreset <robot | media >
     For <robot>, reset the total number of get/put operations and retries.
     For <media>, reset the media drive event statistics
time <print> | <network> | <hh:mm:ss> | <hh:mm>
   Print or set the library's time value. Takes the library off of network time if set. The network option re-enables network time.
   Depending on the network, it may take several minutes to revert back to network time.
trace <trace type> on/off
   Example: trace tti-dbg-01 on
    Turns tti debug log trace on for drive id 1
   Example: trace tti-dbg-18 off
    Turns tti debug log trace off for drive id 18
   Example: trace interface manager-debug on
    Turns IFM debug log trace on
   List of Trace Type Strings That Can Be Used With Trace:
    tti-dbg-xx ( xx is the drive id )
    drive-tti-xx ( xx is the drive id )
    scsi
    scsi-engine
    scsi-server
    interface-manager
    interface-manager-debug
    diag
    event-manager
    OpPanel
    service-interface
    VMonitor
    object-data-store
    access-manager
    sensor-manager
    opel-server
    move-sequence
    lms
upsidedowndetect print
   Show the library's current 'upsidedowndetect' option setting
upsidedowndetect <on|off>
   Set the 'upsidedowndetect on/off' option.
   This option controls whether or not the library detects upside down cartridges.
   This setting is only valid for multi-media modules.
   LTO modules mechanically restrict upside down cartridges.
   Setting option to 'on' will enable checking. This is the default.
   Setting option to 'off' will disable checking.
version print
   Show all library version information
 