| Пример настройки HP Blade Enclosure с7000 при помощи скриптов (Часть 2) |
|
В этой части, приведен пример выполнения скрипта сбора информации с Onboard Administrator`е HP Blade Enclosure с7000
В первой части мы выполнили настройку Onboard Administrator`а при помощи скрипта. Теперь выполним следующий скрипт сбора информации с Onboard Administrator:
show config
show date
show display event
show ebipa
show enclosure fan all
show enclosure info
show enclosure powersupply all
show enclosure status
show enclosure temp
show interconnect info all
show interconnect status all
show interconnect list
show interconnect port map all
show interconnect sessions
show interconnect status all
show ldap
show ldap group list
show ldap certificate
show
networkshow oa info all
show oa network all
show oa status all
show power
show rack name
show server info all
show server list
show server status all
show server port map all
show SNMP
show sshkey
show sshfingerprint
show sso info
show syslog enclosure
show syslog server 1
show syslog server 2
show syslog server 3
show syslog server 4
show syslog server 5
show syslog server 6
show syslog server 7
show syslog server 8
show syslog server 9
show syslog server 10
show syslog server 11
show syslog server 12
show syslog server 13
show syslog server 14
show syslog server 15
show syslog server 16
show topology
show user
show user list
Посмотрим на результат выполнения скрипта:
ISSOA1 [SCRIPT MODE]> show config
ISSOA1 [SCRIPT MODE]> show date
Date: 2010-04-09T21:03:21+02:00 Time Zone: CET
ISSOA1 [SCRIPT MODE]> show display event
Display Events is set to OFF.
ISSOA1 [SCRIPT MODE]> show ebipa
EBIPA Information for Server Blades
-----------------------------------
Enabled : Enabled
Starting Address : xx.xx.xx.161
Subnet Mask : 255.255.255.0
Default Gateway : xx.xx.xx.1
Domain :
DNS Server #1 : xx.xx.35.243
DNS Server #2 : xx.xx.81.243
DNS Server #3 : 0.0.0.0
NTP Server #1 : 0.0.0.0
NTP Server #2 : 0.0.0.0
EBIPA Information for Interconnects
-----------------------------------
Enabled : Enabled
Starting Address : xx.xx.xx.220
Subnet Mask : 255.255.255.0
Default Gateway : xx.xx.xx.1
Domain :
DNS Server #1 : xx.xx.35.243
DNS Server #2 : xx.xx.81.243
DNS Server #3 : 0.0.0.0
NTP Server #1 : 0.0.0.0
NTP Server #2 : 0.0.0.0
ISSOA1 [SCRIPT MODE]> show enclosure fan all
Fan #10 information:
Status: OK
Speed: 40 percent of Maximum speed
Maximum speed: 18000
Minimum speed: 10
Power consumed: 12
Spare Part Number: 412140-B21
Version: 2.7
Diagnostic Status:
Internal Data OK
Location OK
Device Failure OK
Device Degraded OK
Fan #9 information:
Status: OK
Speed: 40 percent of Maximum speed
Maximum speed: 18000
Minimum speed: 10
Power consumed: 20
Spare Part Number: 412140-B21
Version: 2.7
Diagnostic Status:
Internal Data OK
Location OK
Device Failure OK
Device Degraded OK
Fan #8 information:
Status: OK
Speed: 40 percent of Maximum speed
Maximum speed: 18000
Minimum speed: 10
Power consumed: 18
Spare Part Number: 412140-B21
Version: 2.7
Diagnostic Status:
Internal Data OK
Location OK
Device Failure OK
Device Degraded OK
Fan #7 information:
Status: OK
Speed: 40 percent of Maximum speed
Maximum speed: 18000
Minimum speed: 10
Power consumed: 21
Spare Part Number: 412140-B21
Version: 2.7
Diagnostic Status:
Internal Data OK
Location OK
Device Failure OK
Device Degraded OK
Fan #6 information:
Status: OK
Speed: 40 percent of Maximum speed
Maximum speed: 18000
Minimum speed: 10
Power consumed: 21
Spare Part Number: 412140-B21
Version: 2.7
Diagnostic Status:
Internal Data OK
Location OK
Device Failure OK
Device Degraded OK
Fan #5 information:
Status: OK
Speed: 40 percent of Maximum speed
Maximum speed: 18000
Minimum speed: 10
Power consumed: 20
Spare Part Number: 412140-B21
Version: 2.7
Diagnostic Status:
Internal Data OK
Location OK
Device Failure OK
Device Degraded OK
Fan #4 information:
Status: OK
Speed: 40 percent of Maximum speed
Maximum speed: 18000
Minimum speed: 10
Power consumed: 13
Spare Part Number: 412140-B21
Version: 2.7
Diagnostic Status:
Internal Data OK
Location OK
Device Failure OK
Device Degraded OK
Fan #3 information:
Status: OK
Speed: 40 percent of Maximum speed
Maximum speed: 18000
Minimum speed: 10
Power consumed: 22
Spare Part Number: 412140-B21
Version: 2.7
Diagnostic Status:
Internal Data OK
Location OK
Device Failure OK
Device Degraded OK
Fan #2 information:
Status: OK
Speed: 40 percent of Maximum speed
Maximum speed: 18000
Minimum speed: 10
Power consumed: 18
Spare Part Number: 412140-B21
Version: 2.7
Diagnostic Status:
Internal Data OK
Location OK
Device Failure OK
Device Degraded OK
Fan #1 information:
Status: OK
Speed: 40 percent of Maximum speed
Maximum speed: 18000
Minimum speed: 10
Power consumed: 20
Spare Part Number: 412140-B21
Version: 2.7
Diagnostic Status:
Internal Data OK
Location OK
Device Failure OK
Device Degraded OK
ISSOA1 [SCRIPT MODE]> show enclosure info
Enclosure Information:
Enclosure Name: TOP
Enclosure Type: BladeSystem c7000 Enclosure
Onboard Administrator Hardware Version: 1.00
Part Number: 412152-B21
Serial Number: GB8631F7EP
UUID: 09GB8631F7EP
Asset Tag: Production_HPC1
Chassis Spare Part Number: 412152--21
Power Distribution Unit:
PDU Type: Unknown
PDU Part Number: 413374-B21
Onboard Administrator Tray Information:
Type: HP BladeSystem c7000 Onboard Administrator Tray
Part Number: 416000-001
Serial Number: OI66MZ0120
ISSOA1 [SCRIPT MODE]> show enclosure powersupply all
Power Supply Information and Status
Power Supply #6 Information:
Status: OK
AC Input Status: OK
Capacity: 2250 Watts
Current Power Output: 179 Watts
Serial Number: 5A22B0AHLTB00X
Diagnostic Status:
Internal Data OK
Device Failure OK
AC Cord OK
Power Supply #5 Information:
Status: OK
AC Input Status: OK
Capacity: 2250 Watts
Current Power Output: 179 Watts
Serial Number: 5A22B0AHLTB0DM
Diagnostic Status:
Internal Data OK
Device Failure OK
AC Cord OK
Power Supply #4 Information:
Status: OK
AC Input Status: OK
Capacity: 2250 Watts
Current Power Output: 179 Watts
Serial Number: 5A22B0AHLT806H
Diagnostic Status:
Internal Data OK
Device Failure OK
AC Cord OK
Power Supply #3 Information:
Status: OK
AC Input Status: OK
Capacity: 2250 Watts
Current Power Output: 179 Watts
Serial Number: 5A22B0AHLTB0EG
Diagnostic Status:
Internal Data OK
Device Failure OK
AC Cord OK
Power Supply #2 Information:
Status: OK
AC Input Status: OK
Capacity: 2250 Watts
Current Power Output: 179 Watts
Serial Number: 5A22B0AHLTB00K
Diagnostic Status:
Internal Data OK
Device Failure OK
AC Cord OK
Power Supply #1 Information:
Status: OK
AC Input Status: OK
Capacity: 2250 Watts
Current Power Output: 179 Watts
Serial Number: 5A22B0AHLT806M
Diagnostic Status:
Internal Data OK
Device Failure OK
AC Cord OK
ISSOA1 [SCRIPT MODE]> show enclosure status
Enclosure:
Status: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Redundancy OK
Onboard Administrator:
Status: OK
Power Subsystem:
Status: OK
Redundancy: AC Redundant
Total Capacity: 13500 Watts
Redundant Capacity: 6750 Watts
InputPower: 1533 Watts
PS Good/Wanted/Needed: 6/2/1
Cooling Subsystem:
Status: OK
Fans Good/Wanted/Needed: 10/8/7
ISSOA1 [SCRIPT MODE]> show enclosure temp
Locale Status Temp Caution Critical
------------------------- ------ -------- ------- --------
Enclosure OK 18C/ 64F 38C 43C
Onboard Administrator 1 OK 34C/ 93F 75C 80C
Onboard Administrator 2 OK 34C/ 93F 75C 80C
Blade Bay 2 OK 18C/ 64F 38C 43C
Blade Bay 3 OK 16C/ 60F 38C 43C
Blade Bay 4 OK 13C/ 55F 38C 43C
Blade Bay 5 OK 16C/ 60F 38C 43C
Interconnect Module 1 OK ---- --- ---
Interconnect Module 2 OK ---- --- ---
Interconnect Module 5 OK ---- --- ---
Interconnect Module 6 OK ---- --- ---
ISSOA1 [SCRIPT MODE]> show interconnect info all
8.
7.
6. Fiber Single Brocade 4/24 SAN Switch for HP c-Class BladeSystem URL:http://xx.xx.xx.202
P/N:AE372A S/N:CN86257049 SerPortRoute:1 EthPortRoute:1
Name:swd77 IP:xx.xx.xx.202
PrtDis:AfterBoot TmpSen:Present JS2Conn:Absent EthExtIf:Absent
EthOAIf:Present Baud:9600 SerExtIf:Present SerOAIf:Present
5. Fiber Single Brocade 4/24 SAN Switch for HP c-Class BladeSystem URL:http://xx.xx.xx.201
P/N:AE372A S/N:CN86237KKY SerPortRoute:1 EthPortRoute:1
Name:swd77 IP:xx.xx.xx.201
PrtDis:AfterBoot TmpSen:Present JS2Conn:Absent EthExtIf:Absent
EthOAIf:Present Baud:9600 SerExtIf:Present SerOAIf:Present
4.
3.
2. Ethernet Single GbE2c Ethernet Blade Switch URL:
P/N:VARIOUS S/N:MY362TTENS SerPortRoute:0 EthPortRoute:0
Name: IP:0.0.0.0
PrtDis:AfterBoot TmpSen:Present JS2Conn:Absent EthExtIf:Present
EthOAIf:Present Baud:9600 SerExtIf:Present SerOAIf:Absent
1. Ethernet Single GbE2c Ethernet Blade Switch URL:
P/N:VARIOUS S/N:MY3EE90EP9 SerPortRoute:0 EthPortRoute:0
Name: IP:0.0.0.0
PrtDis:AfterBoot TmpSen:Present JS2Conn:Absent EthExtIf:Present
EthOAIf:Present Baud:9600 SerExtIf:Present SerOAIf:Absent
ISSOA1 [SCRIPT MODE]> show interconnect status all
Interconnect Module #8 Status:
Interconnect Module Type: No Interconnect Module Installed
Interconnect Module #7 Status:
Interconnect Module Type: No Interconnect Module Installed
Interconnect Module #6 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
Powered: On
Diagnostic Status:
Management Processor OK
Thermal Warning OK
Thermal Danger OK
Device Failure OK
Device Degraded OK
Interconnect Module #5 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
Powered: On
Diagnostic Status:
Management Processor OK
Thermal Warning OK
Thermal Danger OK
Device Failure OK
Device Degraded OK
Interconnect Module #4 Status:
Interconnect Module Type: No Interconnect Module Installed
Interconnect Module #3 Status:
Interconnect Module Type: No Interconnect Module Installed
Interconnect Module #2 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
Powered: On
Diagnostic Status:
Management Processor OK
Thermal Warning OK
Thermal Danger OK
Device Failure OK
Device Degraded OK
Interconnect Module #1 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
Powered: On
Diagnostic Status:
Management Processor OK
Thermal Warning OK
Thermal Danger OK
Device Failure OK
Device Degraded OK
ISSOA1 [SCRIPT MODE]> show interconnect list
Bay Interconnect Type Manufacturer Power Health UID
--- ----------------- ------------------- ----- --------- ---
1 Ethernet HP On OK Off
2 Ethernet HP On OK Off
3 [Absent]
4 [Absent]
5 Fiber Channel BROCADE On OK Off
6 Fiber Channel BROCADE On OK Off
7 [Absent]
8 [Absent]
Totals: 4 interconnect modules installed, 4 powered on.
ISSOA1 [SCRIPT MODE]> show interconnect port map all
8:
7:
6: Brocade 4/24 SAN Switch for HP c-Class BladeSystem
Type: Fiber
Width: Single
Status: OK
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Status OK OK
Blade 3 5
Mezz/Nic 2 2
Port 2 2
5: Brocade 4/24 SAN Switch for HP c-Class BladeSystem
Type: Fiber
Width: Single
Status: OK
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Status OK OK
Blade 3 5
Mezz/Nic 2 2
Port 1 1
4:
3:
2: GbE2c Ethernet Blade Switch
Type: Ethernet
Width: Single
Status: OK
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Status OK OK OK OK OK OK OK
Blade 2 3 4 5 2 3 4
Mezz/Nic NI NI NI NI NI NI NI
Port 4 4 4 2 2 2 2
1: GbE2c Ethernet Blade Switch
Type: Ethernet
Width: Single
Status: OK
Port 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Status OK OK OK OK OK OK OK
Blade 2 3 4 5 2 3 4
Mezz/Nic NI NI NI NI NI NI NI
Port 3 3 3 1 1 1 1
ISSOA1 [SCRIPT MODE]> show interconnect sessions
Interconnect Bay User
------------------ --------------
No Interconnect remote console sessions were detected.
ISSOA1 [SCRIPT MODE]> show interconnect status all
Interconnect Module #8 Status:
Interconnect Module Type: No Interconnect Module Installed
Interconnect Module #7 Status:
Interconnect Module Type: No Interconnect Module Installed
Interconnect Module #6 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
Powered: On
Diagnostic Status:
Management Processor OK
Thermal Warning OK
Thermal Danger OK
Device Failure OK
Device Degraded OK
Interconnect Module #5 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
Powered: On
Diagnostic Status:
Management Processor OK
Thermal Warning OK
Thermal Danger OK
Device Failure OK
Device Degraded OK
Interconnect Module #4 Status:
Interconnect Module Type: No Interconnect Module Installed
Interconnect Module #3 Status:
Interconnect Module Type: No Interconnect Module Installed
Interconnect Module #2 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
Powered: On
Diagnostic Status:
Management Processor OK
Thermal Warning OK
Thermal Danger OK
Device Failure OK
Device Degraded OK
Interconnect Module #1 Status:
Status : OK
Thermal: OK
CPU Fault: OK
Health LED: OK
UID: Off
Powered: On
Diagnostic Status:
Management Processor OK
Thermal Warning OK
Thermal Danger OK
Device Failure OK
Device Degraded OK
ISSOA1 [SCRIPT MODE]> show ldap
Directory Services (LDAP)
Enabled : Disabled
Local Users Enabled : Enabled
NT Name Mapping : Disabled
Directory Server :
Directory Server SSL Port : 0
Search Context #1 :
Search Context #2 :
Search Context #3 :
ISSOA1 [SCRIPT MODE]> show ldap group list
No LDAP groups were detected.
ISSOA1 [SCRIPT MODE]> show ldap certificate
No certificates were found.
ISSOA1 [SCRIPT MODE]> show network
Onboard Administrator Network Settings:
DHCP: Disabled IP Address: xx.xx.xx.180
Netmask: 255.255.255.0
Gateway Address: xx.xx.xx.1
Primary DNS: xx.xx.35.243
Secondary DNS: xx.xx.81.243
MAC Address: 00:16:35:5E:76:59
Onboard Administrator Protocol Status:
Web (HTTP/HTTPS): Enabled
SNMP: Enabled
SecureSH: Enabled
Trusted Hosts: Disabled
SSO Trust Mode: Off
Telnet: Enabled
AlertMail: Enabled
Mailbox: info@
fcoe.ru SMTP Server: 192.168.0.1
Sender Domain: Not Set
EBIPA (Server Blades): Enabled
EBIPA (Interconnect Bays): Enabled
XML Reply: Enabled
NTP: Disabled
Primary NTP server: Not Set
Secondary NTP server: Not Set
Server Poll-Interval: 720 seconds
ISSOA1 [SCRIPT MODE]> show oa info all
Onboard Administrator #2 information:
Product Name : BladeSystem c7000 Onboard Administrator
Part Number : 407296-001
Serial Number : O967MK0248
UUID : 09O967MK0282
Manufacturer : HP
Onboard Administrator #1 information:
Product Name : BladeSystem c7000 Onboard Administrator
Part Number : 407296-001
Serial Number : O966MK0096
UUID : 09O966MK0084
Manufacturer : HP
ISSOA1 [SCRIPT MODE]> show oa network all
Onboard Administrator #2 Network Information:
DHCP: Enabled - Dynamic DNS
IP Address: 0.0.0.0
Netmask: 0.0.0.0
Gateway Address: 0.0.0.0
Primary DNS: 0.0.0.0
Secondary DNS: 0.0.0.0
MAC Address: 00:16:35:5E:A6:7F
Link Status: Not Active
Onboard Administrator #1 Network Information:
DHCP: Disabled
IP Address: xx.xx.xx.180
Netmask: 255.255.255.0
Gateway Address: xx.xx.xx.1
Primary DNS: xx.xx.35.243
Secondary DNS: xx.xx.81.243
MAC Address: 00:16:35:5E:76:59
Link Status: Active
ISSOA1 [SCRIPT MODE]> show oa status all
Onboard Administrator #2 Status:
Name: OA-0016355EA67E
Role: Standby
UID: Off
Status: OK
Onboard Administrator #1 Status:
Name: ISSOA1
Role: Active
UID: Off
Status: OK
ISSOA1 [SCRIPT MODE]> show power
Redundancy Configuration: AC Redundant
Dynamic Power Savings: Off
Limit AC Input: Not Set
Capacity: 13500 W
Redundant Capacity: 6750 W
Redundant Power: 6750 W
Power Allocated: 2227 W
Present Power: 1534 W
Maximum Consumable Power: 8208 W
ISSOA1 [SCRIPT MODE]> show rack name
Rack Name: MCSrack
ISSOA1 [SCRIPT MODE]> show server info all
Server Blade #16 Information:
Server Blade Type: No Server Blade Installed
Server Blade #15 Information:
Server Blade Type: No Server Blade Installed
Server Blade #14 Information:
Server Blade Type: No Server Blade Installed
Server Blade #13 Information:
Server Blade Type: No Server Blade Installed
Server Blade #12 Information:
Server Blade Type: Bay Subsumed
Server Blade #11 Information:
Server Blade Type: Bay Subsumed
Server Blade #10 Information:
Server Blade Type: Bay Subsumed
Server Blade #9 Information:
Server Blade Type: No Server Blade Installed
Server Blade #8 Information:
Server Blade Type: No Server Blade Installed
Server Blade #7 Information:
Server Blade Type: No Server Blade Installed
Server Blade #6 Information:
Server Blade Type: No Server Blade Installed
Server Blade #5 Information:
Type: ProLiant BL460c G1
Spare Part Number: 404664-b21
Serial Number: CZJ6360459
Blade ROM Version: I15 06/16/2006
NIC #1 MAC Address: 00:18:FE:32:79:12
NIC #2 MAC Address: 00:00:00:00:00:00
Management Processor Information:
Type: iLO2
Name: ILOCZJH9
Firmware Version: 1.22 Aug 11 2006
IP Address: xx.xx.xx.185
MAC Address: 00:18:FE:32:38:2E
Server Blade #4 Information:
Type: ProLiant BL480c G1
Spare Part Number: 407461-b21
Serial Number: GB8634J350
Blade ROM Version: I14 06/21/2006
NIC #1 MAC Address: 00:16:35:C6:37:D8
NIC #2 MAC Address: 00:16:35:C6:37:DA
NIC #3 MAC Address: 00:16:35:C6:04:69
NIC #4 MAC Address: 00:16:35:C6:04:6A
Management Processor Information:
Type: iLO2
Name: ILOGB840
Firmware Version: 1.20
IP Address: xx.xx.xx.184
MAC Address: 00:16:35:C6:67:7A
Server Blade #3 Information:
Type: ProLiant BL480c G1
Spare Part Number: 404704-B21
Serial Number: CZJ62293KC
Blade ROM Version: I14 05/17/2006
NIC #1 MAC Address: 00:16:35:C6:81:B8
NIC #2 MAC Address: 00:16:35:C6:81:B6
NIC #3 MAC Address: 00:16:35:C6:C0:7F
NIC #4 MAC Address: 00:16:35:C6:C0:80
Management Processor Information:
Type: iLO2
Name: ILOCZJKC
Firmware Version: 1.20
IP Address: xx.xx.xx.183
MAC Address: 00:16:35:3D:E0:7E
Server Blade #2 Information:
Type: ProLiant BL480c G1
Spare Part Number: 404704-B21
Serial Number: CZJ62486K9
Blade ROM Version: I14 05/17/2006
NIC #1 MAC Address: 00:16:35:C6:81:72
NIC #2 MAC Address: 00:16:35:C6:81:76
NIC #3 MAC Address: 00:16:35:C6:C0:6F
NIC #4 MAC Address: 00:16:35:C6:C0:70
Management Processor Information:
Type: iLO2
Name: ILOCZJK9
Firmware Version: 1.22 Aug 11 2006
IP Address: xx.xx.xx.182
MAC Address: 00:16:35:3D:11:D2
Server Blade #1 Information:
Server Blade Type: No Server Blade Installed
ISSOA1 [SCRIPT MODE]> show server list
Bay iLO Name iLO IP Address Status Pwr UID Partner
--- ----------------------------- --------------- -------- --- --- -------
1 [Absent]
2 ILOCZJK9 xx.xx.xx.182 OK On Off
3 ILOCZJKC xx.xx.xx.183 OK On Off
4 ILOGB840 xx.xx.xx.184 OK On Off
5 ILOCZJH9 xx.xx.xx.185 OK On Off
6 [Absent]
7 [Absent]
8 [Absent]
9 [Absent]
10 [Subsumed]
11 [Subsumed]
12 [Subsumed]
13 [Absent]
14 [Absent]
15 [Absent]
16 [Absent]
Totals: 4 server blades installed, 4 powered on.
ISSOA1 [SCRIPT MODE]> show server status all
Blade #16 Status:
Power: No Server Blade Installed
Blade #15 Status:
Power: No Server Blade Installed
Blade #14 Status:
Power: No Server Blade Installed
Blade #13 Status:
Power: No Server Blade Installed
Blade #12 Status:
Server Blade Type: Bay Subsumed
Blade #11 Status:
Server Blade Type: Bay Subsumed
Blade #10 Status:
Server Blade Type: Bay Subsumed
Blade #9 Status:
Power: No Server Blade Installed
Blade #8 Status:
Power: No Server Blade Installed
Blade #7 Status:
Power: No Server Blade Installed
Blade #6 Status:
Power: No Server Blade Installed
Blade #5 Status:
Power: On
Current Wattage used: 22
Health: OK
Thermal: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Management Processor OK
Thermal Warning OK
Thermal Danger OK
I/O Configuration OK
Power OK
Cooling OK
Location OK
Device Failure OK
Device Degraded OK
Blade #4 Status:
Power: On
Current Wattage used: 280
Health: OK
Thermal: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Management Processor OK
Thermal Warning OK
Thermal Danger OK
I/O Configuration OK
Power OK
Cooling OK
Location OK
Device Failure OK
Device Degraded OK
Blade #3 Status:
Power: On
Current Wattage used: 402
Health: OK
Thermal: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Management Processor OK
Thermal Warning OK
Thermal Danger OK
I/O Configuration OK
Power OK
Cooling OK
Location OK
Device Failure OK
Device Degraded OK
Blade #2 Status:
Power: On
Current Wattage used: 402
Health: OK
Thermal: OK
Unit Identification LED: Off
Diagnostic Status:
Internal Data OK
Management Processor OK
Thermal Warning OK
Thermal Danger OK
I/O Configuration OK
Power OK
Cooling OK
Location OK
Device Failure OK
Device Degraded OK
Blade #1 Status:
Power: No Server Blade Installed
ISSOA1 [SCRIPT MODE]> show server port map all
Mezz
Mezz Mezz Device Port Interconnect Interconnect
Slot Device Port Status Bay Bay Port Device ID
---- ------ ------ ---------- ------------ ------------ ----------------
------------------------------- Blade 16 -------------------------------
------------------------------- Blade 15 -------------------------------
------------------------------- Blade 14 -------------------------------
------------------------------- Blade 13 -------------------------------
------------------------------- Blade 12 -------------------------------
------------------------------- Blade 11 -------------------------------
------------------------------- Blade 10 -------------------------------
------------------------------- Blade 09 -------------------------------
------------------------------- Blade 08 -------------------------------
------------------------------- Blade 07 -------------------------------
------------------------------- Blade 06 -------------------------------
------------------------------- Blade 05 -------------------------------
1 Not Present
2 QLogic QMH2462 4Gb FC HBA for HP c-Class BladeSystem
Port 1 OK Bay 5 Port 5 50:06:0b:00:00:6a:6e:14
Port 2 OK Bay 6 Port 5 50:06:0b:00:00:6a:6e:16
NICs Embedded Ethernet
Port 1 OK Bay 1 Port 5 00:18:fe:32:79:12
Port 2 OK Bay 2 Port 5 00:18:fe:32:29:06
------------------------------- Blade 04 -------------------------------
1 Not Present
2 Not Present
3 Not Present
NICs Embedded Ethernet
Port 1 OK Bay 1 Port 12 00:16:35:c6:37:d8
Port 2 OK Bay 2 Port 12 00:16:35:c6:37:da
Port 3 OK Bay 1 Port 4 00:16:35:c6:04:69
Port 4 OK Bay 2 Port 4 00:16:35:c6:04:6a
------------------------------- Blade 03 -------------------------------
1 Not Present
2 QLogic QMH2462 4Gb FC HBA for HP c-Class BladeSystem
Port 1 OK Bay 5 Port 3 50:06:0b:00:00:6a:71:34
Port 2 OK Bay 6 Port 3 50:06:0b:00:00:6a:71:36
3 Not Present
NICs Embedded Ethernet
Port 1 OK Bay 1 Port 11 00:16:35:c6:81:b8
Port 2 OK Bay 2 Port 11 00:16:35:c6:81:b6
Port 3 OK Bay 1 Port 3 00:16:35:c6:c0:7f
Port 4 OK Bay 2 Port 3 00:16:35:c6:c0:80
------------------------------- Blade 02 -------------------------------
1 Not Present
2 Not Present
3 Not Present
NICs Embedded Ethernet
Port 1 OK Bay 1 Port 10 00:16:35:c6:81:72
Port 2 OK Bay 2 Port 10 00:16:35:c6:81:76
Port 3 OK Bay 1 Port 2 00:16:35:c6:c0:6f
Port 4 OK Bay 2 Port 2 00:16:35:c6:c0:70
------------------------------- Blade 01 -------------------------------
ISSOA1 [SCRIPT MODE]> show SNMP
SNMP Configuration:
Status: Enabled
System Name: TOP
System Location: Rack1
System Contact: Mike
Read Community Name: public
Write Community Name: private
Trap Receiver IP Address: 192.168.0.9 public
192.168.1.3 public
ISSOA1 [SCRIPT MODE]> show sshkey
This command is reserved for the 'Administrator' account.
ISSOA1 [SCRIPT MODE]> show sshfingerprint
1024 4f:33:22:cb:60:14:c2:17:25:6d:97:b9:59:25:ac:bb /etc/ssh/id_dsa.pub
ISSOA1 [SCRIPT MODE]> show sso info
Sep 6 01:35:28 OA: Time zone changed to CEST-2 .
Sep 6 01:35:30 OA: Interconnect in slot 1 management processor status is good
Sep 6 01:35:30 OA: Interconnect in slot 2 management processor status is good
Sep 6 01:35:30 OA: Interconnect in slot 5 management processor status is good
Sep 6 01:35:30 OA: Interconnect in slot 6 management processor status is good
Sep 6 01:35:30 OA: LCD Status is: OK.
Sep 6 01:35:31 Enclosure-Link: Service started
Sep 6 01:35:32 OA: Redundant Onboard Administrator detected.
Sep 6 01:35:32 OA: Onboard Administrator booted successfully
Sep 6 01:35:37 Redundancy: Service started (ACTIVE)
SSO Trust Mode: Off
No certificates were found.
ISSOA1 [SCRIPT MODE]> show syslog enclosure
ISSOA1 [SCRIPT MODE]> show syslog server 1
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 2
ISSOA1 [SCRIPT MODE]> show syslog server 3
ISSOA1 [SCRIPT MODE]> show syslog server 4
ISSOA1 [SCRIPT MODE]> show syslog server 5
ISSOA1 [SCRIPT MODE]> show syslog server 6
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 7
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 8
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 9
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 10
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 11
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 12
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 13
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 14
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 15
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show syslog server 16
The server blade is not present.
ISSOA1 [SCRIPT MODE]> show topology
Rack Topology (top-down)
Rack UUID: 09GB8968F7K9
Warning! Enclosures have different rack names!
Enclosure Name Rack Name
-------------------------------- --------------------------------
1Z34AB789012 UnnamedRack
TOP UnnamedRack
Bottom UnnamedRack
Enclosure Name Status Local IP Address UUID
-------------------------------- -------- ----- --------------- --------------
1Z34AB789012 OK No 192.168.0.120 09GB9681F7H9
TOP OK Yes xx.xx.xx.180 09GB9681F7EP
Bottom OK No xx.xx.xx.230 09GB9681F7EW
ISSOA1 [SCRIPT MODE]> show user
User "leen" Information:
User Rights: Admin
Server Bay Access List: 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16
Interconnect Bay Access List: 1 2 3 4 5 6 7 8
OA Access: Yes
ISSOA1 [SCRIPT MODE]> show user list
Privilege Acct.
User Name Full Name Level Status
------------- -------------------- ---------- ---------
Administrator http://www.FCoE.ru Admin Enabled
Mike http://www.FCoE.ru Admin Enabled
|